Part Number Hot Search : 
D4SBL M67799M HDCE188G AD640T LTC422 JM20330 33N06 M69000
Product Description
Full Text Search
 

To Download MF600SWI Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Product Specification
MF600SWI
File No Revision System Application Product Type Product Name Date Issued By Approved By Issued Date RDPS-MF051 R1 Mirco Filter For ADSL CPE Side Micro filter MF600SWI OCT. 01th, 2002 Sundi Lin - Design Engineer, R&D_1 sundi@ycl.com.tw Roger Wu - Manager, R&D_1 roger@ycl.com.tw
YCL Electronics Co., Ltd.
No.95, Feng Jen Road, Feng Shan City, Kaohsiung County, Taiwan, R.O.C.
This controlled document is the property of YCL Electronics Co., Ltd. Any duplication reproduction or transmission by unauthorized parties without the prior written permission of YCL Electronics Co., Ltd. is prohibited.
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 1 OF 11
Product Specification
MF600SWI Table of contents
Item Description 1. 2. 3. 4. 5. Introduction Compatibility References Abbreviations Technical requirements 5.1. Schematic 5.2. ZHP-r definition 5.3. Electrical specification 5.4. DC characteristics 5.5. Test methods 5.5.1 . Off-hook insertion loss 5.5.2 . Return loss 5.5.2.1. Complex* return loss with ATU-R 5.5.2.2. 600 ohm return loss with ATU-R Environmental condition 6.1. Resistibility to overvoltage and overcurrents 6.2. Climatic condition 6.2.1. Operating temperature 6.2.2. Storage and transport 6.2.3. Operating humidity Reliabilty conditions 7.1.Thermal shock 7.2. Temperature humidity exposure 7.3. Vibration test Mechanical conditions 8.1. Mechanical --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Page 3 3 4 4 5 5 5 6 8 8 8 9 9 9 10 10 10 10 10 10 10 10 10 10 11 11
6
7
8.
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 2 OF 11
Product Specification
MF600SWI 1. Introduction:
The in-Line Micro filter has been specifically designed to implement the functionality of low pass filter in G.Lite system.G.Lite technology is similar to full rate ADSL in using DMT technology but operates at a lower data rate of up to 1.5Mbps downstream and 512Kbps upstream ,depending on line conditions and lengths.ADSL Lite is proposed as a lower speed version of ADSL that will eliminate the need for telecom to install and maintain a premises based POTS splitter. It was found necessary to include one or more low pass filters in series with the POTS terminals in order to reliably achieve maximum data rates.
For POTS voice band service , the low pass filter provide protection from ADSL signal which may impact through non-line or other effects remote devices(handset, fax, voice band modem etc)and central office operation . For ADSL signal , it also provide protection from the high frequency transient and impedance effect that occur during POTS operation(ringing transients , on-hook,off-hook transient and so on).
Because the POTS splitter connects directly to the subscriber loop media , it must also provide some protection for externally induced line hits or faults which could damage any attached equipment or endanger humans interacting with the installed equipment.The circuit protection will be provided mostly by standard central office line protection means and additional protection measures built into pots splitter to protect against line overstress which could damage the splitter itself.
2. Reference:
Ref. 1 : Ref. 2 : Ref. 3 : ETS 300 001 ANSI T1E1.4 G.992.2 ITU-T K20 Attachment to Public Switched Telephone Network Network and Customer Installation Interface Resistibility of telecommunication switching Equipment to overvoltages and overcurrents Ref. 4 : ITU-T K21 Resistibility of subscribers terminal to overvoltage and overcurrents
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 3 OF 11
Product Specification
MF600SWI 3. Abbreviations:
ADSL CO CPE POTS RT ADSL-NT Asymmetric Digital Subscriber Line Central Office Customer Premise Equipment. Plain Old Telephone Service Remote Terminal Network termination of ADSL
4. Abbreviations:
ADSL CO CPE POTS RT DSL-NT Asymmetric Digital Subscriber Line Central Office Customer Premise Equipment. Plain Old Telephone Service Remote Terminal Network Termination of ADSL
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 4 OF 11
Product Specification
MF600SWI 5. Technical requirements:
5.1. Schematic:
1
The following drawing illustrates the schematic of this product.
5.2. ZHP-r definition: To facilitate testing of the Single In-Line filter independently of the actual modem or specific vendor, ZHP-r is defined to allow proper termination of the ADSL port during voice band testing. The ZHP-r is valid only for voice band frequency. The combination of capacitors in the ZHP-r is only representative. The input shall be 27 nF however derived. ZHP-r equivalent circuit is shown below. 0.056 uF 0.47 mH 100 ohms
0.056 uF
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 5 OF 11
Product Specification
MF600SWI
5.3. Electrical specification: The low pass filter shall satisfy the following parametric limits shown in this table across the Line side of this device. Splitter parameters Splitter bandwidth Nominal voice band Ringing frequency ADSL band Line Impedance ZL Line Impedance ZNL-r Modem impedance Operation voltage voice band Nominal signal Ringing signal DC voltage Max. AC voltage Max. differential Operation current voice band Loop current DC resistance DC resistance Isolation resistance
Differential input blocking impedance
Tip to Tip and Ring to Ring < 50 ohms
Electrical requirements Range Values DC to 4 kHz 0.3 kHz to 3.4 kHz 15.3 Hz to 68 Hz 30 kHz to 1104 kHz 300 Hz to 3.4 kHz 300 Hz to 3.4 kHz 30 kHz to 1104 kHz 600 ohms
1330 ohm // (380 ohm // 0.1F)
100 ohms
21 mVpp to 5.4 Vpp 40 Vrms to 150 Vrms ( 113 Vpp to 424 Vpp ) 0 V to 105 V 150 Vrms with -105 VDC offset 320 V
< 100 mA
Tip to Ring
> 10 Mohms
20 kHz Line side 30 kHz 5 MHz to 10 MHz 10 MHz to 400 MHz Voice band characteristics Insertion loss between 600 ohms resistive single filter With 5 filters
Data sheet subject to change without notice
> 2 kohms > 3 kohms > 2 kohms N/A
1004 Hz 1004 Hz
< 0.7 dB < 1.0 dB
RDPS-MF051(R1)10/01/2002 SHEET 6 OF 11
Product Specification
MF600SWI
Electrical requirements Range 200 to 4 kHz 200 to 4 kHz SRL-L 600 ohms return loss single filter ERL SRL-H SRL-L 600 ohms return loss with 5 filters ERL SRL-H SRL-L Complex* ZNL-r Return loss single filter ERL SRL-H SRL-L Complex* ZNL-r return loss with 5 filters ERL SRL-H < 1.0 dB < 5 dB > 23 dB > 23 dB > 20 dB > 20 dB > 13.5 dB > 7 dB > 26.5 dB > 17 dB > 9 dB > 15 dB > 8 dB > 2 dB Values
Splitter parameters Attenuation distortion between 600 ohms resistive single filter Attenuation distortion between 600 ohms resistive with 5 filters
* 1330 ohms in parallel with the series connection of a 348 ohms resistor and a 100 nF capacitor Longitudinal conversion loss ( LCL ) Delay distortion Inter-Modulation distortion ADSL band characteristics Common mode rejection ADSL band attenuation 40 kHz 1.1 MHz 30 kHz 1 MHz > 45 dB > 45 dB > 24 dB > 65 dB 200 Hz to 1 kHz 1 kHz to 3 kHz 200Hz to 4 kHz 2nd 3nd > 58 dB > 53 dB < 100 s > 57 dB > 60 dB
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 7 OF 11
Product Specification
MF600SWI
5.4. DC characteristics : All requirements of this specification can be met in the presence of all POTS loop currents from 0 mA to 100 mA. This Single In-Line filter can pass POTS tip-to-ring DC voltages of 0 V to 105 V and ringing signals of 40 Vrms to 150 Vrms at any frequencies from 15.3 Hz to 68 Hz superimposed on DC voltages in the range from 0 V to 105 V. The DC resistance from tip-to-ring at the line port interface with the phone interface shorted, shall be less than or equal to 50 ohms for one filter. The DC resistance from tip-to-ground and from ring-toground at the Phone interface with the Line interface open shall be greater than or equal to 10 Megohms. The ground point shall be local building or green wire ground. As an objective, the DC resistance should exceed 10 M. 5.5. Test methods : 5.5.1. Off-hook insertion loss : The insertion loss of a device connected into a given transmission system is defined as the ratio, expressed in dB, of the load power available ( before and after insertion ) delivered to the output network beyond the point of insertion at a given frequency. In general, the insertion loss is defined as the ratio, expressed in dB of the power delivered to a load with the circuit in place and the power delivered to a load without the circuit in place. The added insertion loss shall be measured using the test up in figure 2. For measuring POTS band insertion loss for single filter module also for single filter with four added parallel load filters. General Insertion loss equation can be expressed as follows. Insertion loss = 20 log V2 / V1 dB where V1 = the measured voltage value of load without LPF in circuit. V2 = the measured voltage value of load with LPF in circuit. The test setup is shown in drawing below.
Figure 2.
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 8 OF 11
Product Specification
MF600SWI
5.5.2. Return loss: Return loss measure the amount of energy that is lost due to reflection which resulted from impedance mismatching at the interface. Return loss is essentially defined as the ratio of the power incident upon a given transmission system to the power reflected caused by impedance mismatch with respect to reference impedance at the interface between source and device. Return loss figure are a function of the impedance of the circuit involved and are therefore frequency dependent. These impedance must be closely maintained in order to reduce the possibility of undesirable reflection and echoes which in long distance circuit the telephone user or destroy the data being sent. To perform the return loss test, open, short, load calibration must be done prior measurement while the LCR impedance analyzer being selected in impedance mode. Return loss is general expressed in decibels. General return loss equation is as follows. Return loss = 20 log ZL + ZM / ZL - ZMdB Where ZL = the reference impedance ZM = the measured impedance The test setup is shown in drawing below. 5.5.2.1. Complex* return loss with ATU-R : ZNL-r definition:
Figure 3. 5.5.2.2. 600 ohm return loss with ATU-R :
Figure 4.
Data sheet subject to change without notice RDPS-MF051(R1)10/01/2002 SHEET 9 OF 11
Product Specification
MF600SWI 6. Environmental condition:
6.1. Resistibility to overvoltages and overcurrents: The splitter has to comply with requirements as per ITU-T K.21. 6.2. Climatic conditions: 6.2.1. Operating temperature: Application indoor Long time operation guarantee temperature ( 5 to 40 0C ) Short time operation guarantee temperature ( 0 to 50 0C ) ( According to ETS 300 019, class 3.2 ) 6.2.2. Storage and transport: Low ambient temperature - 20 0C High ambient temperature +85 0C ( According to MIL-STD-202 method 107 ) 6.2.3. Operation humidity: Long time operation guarantee humidity ( 5 to 85 % ) Short time operation guarantee humidity ( 5 to 90 % ) Short time : within 72 continuous hours and 15 days in a year
7. Reliability conditions:
7.1. Thermal shock : Temperature from -20 C to +85 C for 5 cycles (According to MIL-STD-202 , method 107) 7.2. Temperature humidity exposure : +50 C /95RH , 96hrs (According to MIL-STD-202 , method 103) 7.3. Vibration test : Random vibration , frequency 5-500Hz , sweep time :1 hr / axis / Force : 2.4grams (According to MIL-STD-202 , method 204)
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 10 OF 11
Product Specification
MF600SWI 8. Mechanical conditions :
8.1. Mechanical :
Note : Unit : mm
Data sheet subject to change without notice
RDPS-MF051(R1)10/01/2002 SHEET 11 OF 11


▲Up To Search▲   

 
Price & Availability of MF600SWI

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X